AC Replacement Done to Code in Northern Virginia

A cooling system is only as good as the day it went in — the sizing, the line set, the vacuum and the charge decide how it runs for the next fifteen years.

Written price before any work starts · Permits pulled where required · Phones answered 24 hours a day

Gray central air condenser on a black pad in grass beside a house wall and wood fence
Finished AC installation with the condenser set on a level black pad beside the house, tucked between the siding and a wood privacy fence with the lawn regraded around it.

Last updated: Service area: Northern Virginia

Replacing an air conditioner properly means more than swapping the box outside. The outdoor unit and the indoor evaporator coil are a matched pair and are replaced together. The existing copper line set is recovered, flushed with RX11 and nitrogen, pressure-tested and evacuated to a deep vacuum before any refrigerant goes in. The condensate path, the disconnect, the pad and the duct transition are all renewed. The charge is then set by subcooling to the manufacturer's specification and the result verified by measuring the temperature split across the coil.

How an air conditioning installation is sized

Tonnage is not a matter of taste and it is not copied off the old data plate without thought. An oversized system short cycles, never runs long enough to pull humidity out of the air, and leaves a house that is cold and clammy. An undersized one runs all afternoon and never catches up.

The systems we put in run from around one and a half tons in a condo up to five tons in a large house, with two, two and a half, three and three and a half tons covering most of what we install. What settles the number is the house — its volume, its insulation, its glazing, its orientation — together with the duct system that already exists and what the homeowner actually complains about.

  • Where the equipment lives. An attic air handler, a basement furnace and coil, a condo closet and a rooftop package unit are four different jobs with four different constraints.
  • What the ducts can carry. We have run new duct and added vents to rooms that were never served, including opening drywall and a window opening to route a run, and fitting new flexible duct to a kitchen that had no supply at all. Where the duct is the limit, see ductwork repair, sealing and venting.
  • Whether the house should stay on gas at all. Some homeowners take a replacement as the moment to move off gas heat entirely, which turns the job into heat pump repair and installation instead.
  • Zoning or a second system. Where one system cannot serve an area properly, we have priced adding zoning dampers against installing a separate system with its own ductwork, and let the homeowner choose.

What a complete air conditioning replacement includes

A full changeout is a day of ordered steps. Skipping any of them is how a new system ends up performing like the old one:

  1. Recover the existing refrigerant. Legally, before anything is disconnected. Older systems hold R-22 and we recover that too.
  2. Remove the old equipment and haul it away — condenser, coil, pad, disconnect box, drain pan and drain line.
  3. Deal with access. We have removed a water heater to get equipment in and out of a mechanical room, taken out built-in shelving that boxed in a condo air handler, and cut a ceiling for access where there was no other route.
  4. Set the new outdoor unit. A 32 by 32 or 36 by 36 pad, four pump-up risers to lift the unit clear of the ground, and a new disconnect box with fuses.
  5. Set the new indoor equipment. A matched evaporator coil with a new filter drier, brazed connections, and a fabricated sheet metal transition where the coil meets the duct, because the new cabinet is rarely the same size as the old one.
  6. Rebuild the condensate path. A new drain line, an EZ trap with a safety switch, and on attic equipment a drain pan with a float switch that shuts the system down on overflow.
  7. Flush, test, evacuate and charge, then commission the system and show you how it runs.

Outdoor clearances get corrected at the same time. On one job the existing condenser stood two feet from the gas meter and the new unit was relocated to gain the required clearance; on another, a condenser hung on a wall bracket came down onto a proper ground pad, which meant extending the electrical whip and the thermostat wiring to reach it.

Why the line set matters on an AC installation

The copper refrigerant lines between the outdoor unit and the indoor coil are usually buried in a wall or a floor, and replacing them means opening the house up. In most cases they do not have to be replaced — but they absolutely have to be cleaned.

  1. Flush with RX11 and nitrogen. This drives out the old compressor oil, any acid and any moisture. It matters most on a changeout from R-22 to R-410A, because the two refrigerants use different oils and mixing them ruins a new compressor.
  2. Pressure-test with nitrogen, at 150 psi, and watch the gauge. A line set that will not hold nitrogen will not hold refrigerant either.
  3. Pull a deep vacuum, to 500 microns. That is the number our technicians work to. A vacuum boils moisture out of the system; anything left behind turns into acid and destroys the compressor slowly.
  4. Replace the insulation if it has failed. We have pulled attic equipment and found the line set insulation broken down along its whole length, and replaced it as part of the job.

Where there is no existing line set — a new system, a mini split, an addition — we run it. Runs of 25, 30, 40 and 75 feet of line set are all work we have done, along with the matching condensate line and the control wiring.

Why an air conditioning coil is replaced with the condenser

The outdoor unit and the indoor evaporator coil are engineered as a pair. Putting a new condenser onto a coil that is ten or fifteen years old gives you neither the rated efficiency nor a warranty that means anything, and the coil is the component most likely to leak next.

What is being replacedWhat has to go with itWhy
Outdoor condenser onlyThe matched evaporator coil, a new filter drier, the pad, the disconnect and the drain lineA mismatched pair does not deliver its rated capacity, and the old coil is the next leak
Condenser and coil, furnace retainedA sheet metal transition between the new coil and the existing plenumCabinet dimensions change between models; the duct connection has to be fabricated to suit
Full system: furnace, coil and condenserFlue and venting work, gas line reconnection and leak test, return and supply plenum reattachmentThe furnace is the cabinet the coil sits on — see heating and furnace installation
Packaged rooftop or gas package unitA new drain line to the main drain, an EZ trap, and reconnection to the trunk supplyEverything is in one cabinet, so the connections outside it carry the whole job

Evacuation, charging and start-up on a new air conditioner

This is the part of the job a homeowner cannot see and a bad installer can skip. It is also the part that decides whether the equipment lasts.

  • Deep vacuum to 500 microns, held and verified, to pull moisture and non-condensables out of the system before the charge goes in.
  • Charge set by subcooling to the manufacturer's published specification, not by feel and not by a pressure chart alone. Every system we commission gets its charge set this way.
  • Temperature split verified. We measure supply and return air across the coil and record the reading. A delta-T check is the proof that the airflow and the charge are both right.
  • Drain line flushed with nitrogen and the safety switch tested, so the first blocked drain shuts the system down rather than soaking a ceiling.
  • Electrical checked — disconnect, fuses, whip and control wiring — and the thermostat set up and calibrated. Where a homeowner wants a Wi-Fi thermostat fitted with the new system, that happens now; see thermostat installation.

Do you need a permit for air conditioning installation in Virginia?

Yes. A repair does not require a permit; replacing equipment does. We pull and process the permit ourselves, the work is performed according to the Virginia building code, and the job is not closed out until it passes final inspection. On permitted work the final portion of payment is held back until that inspection passes — which is how it should be, and how we have always done it.

Permit practice also drives parts of the scope that a homeowner did not ask for and would not think to compare on a quote: a properly sized disconnect, a correctly supported pad, condensate overflow protection, a drain that discharges somewhere legitimate, and gas and flue work reinstated correctly where a furnace shares the installation. If a previous installer skipped them, they get put right.

Air conditioning replacement or repair: when replacement is right

We repair a great deal more equipment than we replace, and the diagnostics behind that decision are set out on air conditioning repair. Replacement becomes the sensible answer in a few specific situations:

  • A failed compressor, particularly the pattern we see repeatedly of low refrigerant, a burned capacitor and a weak compressor arriving together.
  • A genuine refrigerant leak on an obsolete R-22 system. We have replaced systems where a prior service call found the equipment out of refrigerant with a weak compressor, and replacement was the recommendation rather than another recharge.
  • A leaking evaporator coil on an aged system, where the coil and the condenser are both near the end.
  • A furnace with a rusted or cracked heat exchanger underneath the coil, which is unsafe to run whatever the cooling side is doing.
  • A house being reconfigured. Additions, basement finishes and whole-house renovations all change the load, and we have installed complete systems as part of that work.

How long does an air conditioning installation take?

A straight changeout — condenser, coil and the connections around them — is typically a single day. A full system with the furnace, new venting and a new thermostat generally runs a day or two. Work grows beyond that when the scope does:

  • New ductwork. We have run 40 feet of supply and 40 feet of return converting a house off radiators and baseboards, and 50 feet of duct with ten six-inch runs and sixteen registers for a new system serving part of a home.
  • Access problems: equipment behind a water heater, shelving built around an air handler, a condo with a tight closet, or an attic with a difficult hatch.
  • Two systems in one house. Attic-and-basement pairs are common here, and replacing both at once is a different piece of planning than replacing one.
  • Electrical work. Where the panel has no capacity for the new equipment, that is its own scope — see electrical panel upgrades and replacement.

What air conditioning installation costs, and how we price it

We do not quote equipment by phone and we do not publish prices. Two houses that look identical from the street differ by tonnage, by whether the coil is in an attic or on a furnace, by the state of the line set, by duct and transition work, by clearance problems around the outdoor unit and by what the previous installer left behind.

An estimator visits the property, measures and inspects what is actually there, and gives you a written price for a defined scope before anything is ordered. Permit and processing fees are written into that contract, and the final payment is tied to passing inspection.

Service details

Service areaNorthern Virginia
Phone(703) 256-8080
Emergency service24 hours a day, 7 days a week
Office hoursMonday–Friday 8:00am – 5:00pm
Saturday 9:00am – 12:00pm
Sunday closed
Response timeSame business day during business hours; next business day after hours
EstimatesIn person, at the property. Every job is priced only after a professional estimator has seen the work, we do not quote prices by phone or email, with some exceptions.
LicensingVirginia DPOR class A contractor license #2705070610
PermitsPulled and processed by us where the county requires them, with final inspection
Warranty1-year warranty on labor only

Frequently asked questions

Do I have to replace the indoor coil when I replace the outdoor unit?

In nearly every case, yes. The condenser and the evaporator coil are designed and rated as a matched pair, and pairing new outdoor equipment with an aged coil gives you neither the rated performance nor a meaningful warranty. The old coil is also the component most likely to spring the next leak. We replace the coil with a new filter drier and fabricate a sheet metal transition where the new cabinet meets the existing duct.

Can my existing refrigerant lines be reused?

Usually yes, provided they are sound. We recover the old refrigerant, flush the line set with RX11 and nitrogen to drive out the old oil and any moisture, pressure-test it with nitrogen, and evacuate it to a deep vacuum before charging. That process is what makes reuse safe, and it matters most when converting from R-22 to R-410A because the two use different oils. Where the insulation has broken down, we replace it.

What does pulling a vacuum to 500 microns actually do?

It boils moisture and air out of the sealed refrigerant circuit before the charge goes in. Any water left inside combines with refrigerant and oil to form acid, which attacks the compressor windings from the inside over months and years. Non-condensable air raises head pressure and costs capacity. Five hundred microns is the target our technicians evacuate to, and it is verified on a gauge rather than guessed at by time.

How do you know the system is charged correctly?

We set the charge by subcooling to the manufacturer's published specification for that model, rather than by pressure alone or by how the line feels. Then we verify the result by measuring the temperature split across the coil — supply air against return air — and record it. If the split is wrong, either the charge or the airflow is wrong, and both get corrected before we leave.

Do you pull permits for air conditioning replacement?

Yes. Equipment replacement requires a permit, and we pull and process it ourselves rather than asking the homeowner to. The work is performed according to the Virginia building code and the job is not closed out until it passes final inspection. Permit and processing fees are written into the contract, and on permitted work the last portion of payment is held until the inspection has passed.

What size air conditioner does my house need?

It depends on the house, not on the label of the old unit. Volume, insulation, glazing, orientation and the capacity of the existing duct system all feed into it, along with what is actually going wrong now. We install from around one and a half tons up to five tons. An oversized system short cycles and leaves the house cold and damp; an undersized one runs all day and never catches up.

Can you add cooling to rooms that do not have any?

Yes, and we do it two ways. Where the existing system has capacity, we extend the duct — we have run new trunk and flexible duct, opened drywall to route it and added registers to bedrooms, a living room, a hallway and a kitchen that had none. Where duct cannot reasonably be run, a ductless mini split with wall-mounted heads is the alternative, and it needs only a line set, a drain and communicating wiring.

What refrigerant will my new system use?

Current equipment ships with R-454B, and we install and service it. Systems we installed over the previous decade or so use R-410A, sold as Puron, which we also still service and charge. Neither can be mixed with the obsolete R-22 found in older equipment, which is why an R-22 changeout always includes recovering the old charge and flushing the existing lines before the new system is connected.

Our own work on this

Photographs from jobs this company has carried out. No stock photography, no other contractor’s work.

Air conditioner condenser on a flat rooftop deck next to a white vinyl railing under an overcast sky
Rooftop AC installation on a flat roof deck: the new condenser sits on a raised stand beside a white vinyl railing, with the line set run down through the roof.
Condenser on blocks over a river-rock bed against a light gray block wall with a disconnect box above
Completed AC installation with the condenser raised on blocks over a river-rock bed against a painted block wall, with the electrical disconnect mounted above and gauges still hooked up for the final charge check.
New AC condenser beside a cream vinyl-sided house with maroon shutters, groundcover around the pad
New AC condenser installed along the side of a house with cream vinyl siding and maroon shutters, set on a pad in the groundcover with the refrigerant lines entering the wall behind it.
AC condenser on a black pad under a window with a gray disconnect box mounted on cream siding
AC installation finished below a window: the condenser sits on a black pad with the electrical disconnect box mounted on the siding and the whip and line set run neatly into the wall.
Large gray AC condenser on a fresh concrete pad at the corner of a house with gray vinyl siding
Large replacement condenser set on a new concrete pad at the corner of a gray vinyl-sided house as part of a full AC installation, with the disconnect switch mounted on the wall beside it.

Licensing, insurance and guarantee

Virginia licensed contractorDPOR license #2705070610
Licensed · Bonded · InsuredFor residential and light commercial work
Serving since 199927 years in Northern Virginia

Related services

Areas we serve

Book a written estimate for a new cooling system

Call and speak to a licensed Northern Virginia contractor. Every call is scheduled as soon as the calendar allows, and genuine emergencies are dispatched around the clock.

(703) 256-8080 Estimate